| 1. Is the power cord connected between your wall outlet and the X-300 socket ?\\ | 1. Is the power cord connected between your wall outlet and the X-300 socket ?\\ | ||
| - | 2. Does your wall outlet supply power? | + | 2. Does your wall outlet supply power? |
| - | 3. Are the two glass fuses inside the main filter still OK? They sit just near the power cord socket.\\ | + | 3. Are the two glass fuses inside the main filter still OK? They sit just near the power cord socket. Check them with an Ohm-meter.\\ |
| 4. When switching on the machine, do you hear the fan and do you hear the motors locking? | 4. When switching on the machine, do you hear the fan and do you hear the motors locking? | ||
| - | 5. Or the 48 VDC power supply might be defective.\\ | + | 5. If the power switch is OK, the 48 VDC power supply might be defective. It feeds the fan and the step drives.\\ |
| - | 6. Does your | + | 6. With the protective cover OPEN, and trying to home the spincle {{: |
| + | 7. If you see this image and the machine does still not look for its home when pushing {{: | ||
| + | |||
| + | |||
| + | **Continue to [[spindle_not_rotating|trouble shooting, spindle does not rotate]].**\\ | ||
| + | **Continue to [[: | ||